24 CFR §200.940 — Supplementary specific requirements under the HUD building product standards and certification program for sealed insulating glass units

fha-24cfr-200-940

24 CFR §200.940, Supplementary specific requirements under the HUD building product standards and certification program for sealed insulating glass units. An FHA program rule in Subpart S—Minimum Property Standards of 24 CFR Part 200 (Introduction to FHA Programs).

This register: .xlsx .csv

Verbatim regulatory text (3)

Verbatim provisions from 24 CFR §200.940 — Supplementary specific requirements under the HUD building product standards and certification program for sealed insulating glass units — each quote is a verified substring of the regulator-published source snapshot, not retyped. Quoted for reference; this is not legal advice. The operational layer (P&P updates, prompts) lives in the regulation update kits.

24 CFR §200.940(a)

(a) Applicable standards. (1) All sealed insulating glass units shall be designed, manufactured, and tested in compliance with the American Society for Testing and Materials standard: ASTM E-774-92 Standard Specification for Sealed Insulating Glass Units. (2) This standard has been approved by the Director of the Federal Register for incorporation by reference. The standard is available from the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103. This standard is also available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html.

Source: 24 CFR §200.940(a) · source URL · snapshot b2c7a4a2e4bc1fcf

24 CFR §200.940(b)

(b) Labeling. Under the procedures set forth in § 200.935(d)(6) concerning labeling of a product, the administrator's validation mark and the manufacturer's certification of compliance with the applicable standards are issued by the administrator to the manufacturer. Each sealed insulating glass unit shall be marked as conforming to UM 82a. The label shall be located on each sealed insulating unit so that it is available for inspection. The label shall include the manufacturer's name and plant location.

Source: 24 CFR §200.940(b) · source URL · snapshot b2c7a4a2e4bc1fcf

24 CFR §200.940(c)

(c) Periodic tests and quality assurance inspections. Under the procedures set forth in § 200.935(d)(8) concerning periodic tests and quality assurance inspections, the frequency of testing for a product shall be described in the specific building product certification program. In the case of sealed insulating glass units, testing and inspection shall be conducted as follows: (1) At least once a year, the administrator shall visit the manufacturer's facility to select a sample, of the maximum size commercially available, for testing in a laboratory approved by the administrator. (2) The administrator shall also review the quality assurance procedures twice a year to assure that they are being followed by the manufacturer.

Source: 24 CFR §200.940(c) · source URL · snapshot b2c7a4a2e4bc1fcf

Get this regulation in your AI window

Put the verbatim text and its effective date in front of your assistant, instead of whatever it remembers.

Add to Claude Add to ChatGPT

Add to Claude shows the one-time setup: paste one address, no account with us. Add to ChatGPT adds the free C4C app from ChatGPT’s app directory. Either way it’s free.

Get notified if this rule changes

One email when 24 CFR §200.940 — Supplementary specific requirements under the HUD building product standards and certification program for sealed insulating glass units changes: what changed, the new verbatim text, and the effective date. Nothing else.

Double opt-in: we send a confirmation link first. Following one section does not subscribe you to anything else. Privacy.

Source of record: https://claudeforcompliance.com/regs/fha-24cfr-200-940/ · register fha-24cfr-200-940 · verbatim, source-snapshotted regulator text from the Claude for Compliance corpus. To work from every register at once, download the corpus and follow the methodology.